TE_DOUT_FP_SEL=FIX, TE_IO_MODE=TE_RICO, TE_MODE=TE_FFT, TE_DIN_FP_SEL=FIX, TE_PTS=TE64PTS
transmit engine control register
TE_MODE | TE compute mode 0 (TE_FFT): FFT 1 (TE_IFFT): IFFT 2 (TE_DCT): DCT 3 (TE_IDCT): IDCT |
TE_IO_MODE | TE input & output mode select 0 (TE_RICO): real input, complex output 1 (TE_CICO): complex input, complex output 2 (TE_RIRO): real input, real output |
TE_PTS | TE compute point 0 (TE64PTS): 64 points 1 (TE128PTS): 128 points 2 (TE256PTS): 256 points |
TE_DIN_FP_SEL | TE input data format select 0 (FIX): fix 1 (FLT): float |
TE_DOUT_FP_SEL | TE output data format select 0 (FIX): fix 1 (FLT): float |
TE_SCALE | TE scale |
TE_PAUSE_LVL | Transfer Engine stop level for debug use only. |